E09
Calpeda
Earth Leakage / Ground Fault Detected
Controller displays E09 and pump stops abruptly during operation
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insulation breakdown in Calpeda motor windings, Water ingress into Calpeda motor terminal box, Damaged power cable to Calpeda pump, Faulty RCD/GFCI feeding Calpeda system
How to Fix / Troubleshooting
Safety first: Do not repeatedly reset an RCD/GFCI that trips. There may be a dangerous fault. Isolate power and keep the area dry.
- Inspect cable and junctions: Check the entire length of the pump power cable for cuts, abrasions, or crushed sections. Replace damaged cable immediately.
- Check motor terminal box for moisture: Open the Calpeda motor terminal box and look for condensation, corrosion, or water. Dry thoroughly, clean terminals, and replace any compromised gaskets or cable glands.
- Insulation resistance test: Using a megohmmeter (500 V), measure insulation resistance between each motor lead and earth. Values below 1 MΩ indicate serious insulation problems; the motor should be repaired or replaced.
- Verify RCD/GFCI operation: Test the device using its test button. If it trips erratically with other loads, it may be faulty and require replacement by an electrician.
- Do not bypass safety devices: Never bypass earth leakage protection to keep the pump running. Resolve the underlying fault before returning the pump to service.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Calpeda pool pump motor