E10
Calpeda Overload / Torque Limit Exceeded

Variable-speed Calpeda pump shows E10 and cannot reach set RPM

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Impeller partially blocked in Calpeda pump housing, Excessive system backpressure from closed valves or dirty filter, Incorrect maximum current parameter in Calpeda VFD, Mechanical binding in Calpeda motor bearings

How to Fix / Troubleshooting

Safety first: Turn off power and close isolation valves before opening the pump.

  • Inspect and clean impeller: Remove the pump lid and basket. If necessary, disconnect the pump from the plumbing and open the volute to access the impeller. Remove debris such as stones, cable ties, or fibrous material wrapped around the impeller.
  • Check system pressure: Read the filter pressure gauge. If it is significantly higher than normal, backwash or clean the filter to reduce backpressure.
  • Verify valve positions: Ensure return and suction valves are fully open. Partially closed valves increase load on the pump.
  • Check motor bearings: With the pump disassembled and power off, spin the motor shaft by hand. It should rotate freely without grinding. Stiff or noisy bearings indicate the need for motor or bearing replacement.
  • Adjust VFD parameters: In the Calpeda controller menu, verify that the rated motor current and torque limits match the motor nameplate. Incorrect settings can cause premature overload trips.
Advertisements

Repair Difficulty

Hard 4/5