E15
Calpeda
External Interlock / Safety Chain Open
Controller shows E15 and pump stops when external safety input is triggered
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open flow switch wired to Calpeda controller safety input, Tripped low-water level switch in balance tank, Emergency stop button activated, Broken wire in safety interlock loop
How to Fix / Troubleshooting
Safety first: Identify why the safety device has opened before attempting to bypass or reset it.
- Check all safety devices: Locate flow switches, level switches, and emergency stop buttons connected to the Calpeda controller. Ensure they are in the correct operating position and not mechanically stuck.
- Inspect wiring loop: Trace the safety circuit wiring and look for loose terminals, broken conductors, or corroded contacts. Repair or replace as needed.
- Verify actual conditions: Confirm that there is adequate water level and flow. Do not override a safety device if the condition it monitors is not satisfied.
- Reset safety devices: Reset any tripped emergency stops or manual reset switches. Then clear the E15 error on the controller and test operation.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Calpeda controller safety input circuit
Check Price on Amazon