Calpeda Insufficient Turnover / Incorrect Speed Setting

Pump runs but water appears cloudy and circulation seems poor despite normal pressure

Advertisements

Possible Causes

Variable-speed Calpeda pump set to too low RPM, Timer settings not providing enough daily run time, Oversized pool relative to Calpeda pump flow at current speed, Partially blocked impeller reducing actual flow

How to Fix / Troubleshooting

Safety first: Adjusting speed and timers is generally safe, but avoid opening electrical enclosures with power on.

  • Increase pump speed: On variable-speed Calpeda models, raise the RPM to the manufacturer-recommended level for filtration and observe circulation at the pool returns.
  • Extend run time: Adjust the controller timer to run the pump long enough to achieve at least one full pool volume turnover per day (often 8–12 hours, depending on flow).
  • Inspect impeller: If flow seems weak even at higher speeds, check the impeller for debris or scale buildup and clean as needed.
  • Verify filter condition: Ensure the filter media is clean and in good condition; poor filtration can mimic low circulation.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Calpeda variable-speed controller settings
Check Price on Amazon

We may earn a commission from links on this page.