Calpeda Short Cycling / Control Instability

Pump starts and stops repeatedly every few seconds

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty pressure or flow switch connected to Calpeda pump, Incorrect control setpoints in Calpeda controller, Air in system causing fluctuating pressure, Oversized pump for small system volume

How to Fix / Troubleshooting

Safety first: Turn off power before adjusting switches or opening the system.

  • Observe control signals: Watch the pressure or flow switch status LEDs (if present) while the pump runs. Rapid on/off indicates a faulty or misadjusted switch.
  • Adjust setpoints: In the Calpeda controller, review start/stop thresholds and differential settings. Increase the differential to reduce cycling frequency.
  • Bleed air from system: Open air bleed valves on filters or high points in the piping to remove trapped air that may cause pressure spikes.
  • Replace faulty switch: If a pressure or flow switch chatters or has inconsistent readings, replace it with a Calpeda-approved component.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Calpeda pressure/flow switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements