Calpeda Short Circuit / Locked Rotor

Pump trips the circuit breaker immediately when switched on

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted windings in Calpeda motor, Seized rotor due to failed bearings, Water ingress causing internal motor short, Incorrectly sized breaker for Calpeda pump rating

How to Fix / Troubleshooting

Safety first: Do not repeatedly reset a breaker that trips instantly. Isolate power and investigate.

  • Check motor rotation by hand: With power off, attempt to spin the motor fan or shaft. If it does not move or is very stiff, the rotor is likely seized and the motor must be repaired or replaced.
  • Inspect for water ingress: Look for signs of water inside the motor terminal box or rust on the motor body. If present, the motor insulation may be compromised.
  • Measure winding resistance: Disconnect the motor leads and measure resistance between phases (or between run/start windings on single-phase). Very low resistance or a reading to earth indicates a short.
  • Verify breaker size: Confirm that the breaker rating matches Calpeda's recommendations for the pump's full-load current. An undersized breaker may nuisance-trip but will not usually trip instantly.
  • Replace faulty motor: If a short or seizure is confirmed, replace the Calpeda motor with an identical specification unit.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Calpeda pool pump motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements