Possible Causes
Invalid motor data entered, incompatible parameter combination, corrupted configuration memory
How to Fix / Troubleshooting
Safety: Only trained personnel should alter controller parameters.
- Review recent changes: Note any parameters recently modified in the Certikin controller (motor current, voltage, frequency, control mode).
- Restore defaults: Use the controller menu to load factory default settings, then re‑enter motor nameplate data exactly as shown on the Certikin pump motor.
- Check firmware: Ensure the controller firmware version is compatible with the pump model; update if recommended by Certikin.
If E14 persists, the controller memory may be corrupted and the unit may require replacement.