E08
DAB
Ground Fault / Earth Leakage Detection
Pump display shows E08 and unit shuts down shortly after start
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Moisture inside motor terminal box, Damaged motor winding insulation, Water ingress into DAB control module, Damaged power cable or plug
How to Fix / Troubleshooting
Safety first: This is a potential electric shock hazard. Do not attempt to run the pump until the fault is resolved. Isolate power at the breaker and use an RCD/GFCI‑protected circuit.
Steps to check:
- Inspect cable and plug: Look for cuts, crushed sections, or burn marks on the DAB pump power cable and plug. Replace if damaged.
- Check terminal box: Open the motor terminal cover. If you see water, rust, or condensation, dry the area thoroughly and identify the source of ingress (cracked grommet, missing gasket).
- Insulation test (by electrician): Have an electrician perform an insulation resistance test between windings and earth. Low resistance indicates a motor fault.
- Drying and sealing: If moisture was the only issue and insulation tests are good, dry the motor and reseal gaskets and cable entries.
- Persistent E08 or tripping RCD: Replace the motor assembly or DAB control module as recommended by a qualified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
DAB pump motor assembly
Check Price on Amazon
We may earn a commission from links on this page.