E10
DAB Dry‑Run / No‑Water Protection

Pump display shows E10 and unit will not start, often after being stored or unused for a long period

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pump not properly primed, Air leak on suction side, Blocked suction line or closed suction valve, Faulty flow or pressure sensor in DAB pump

How to Fix / Troubleshooting

Safety first: Turn off power before opening the pump lid. Never run the pump dry; it can destroy the mechanical seal.

Steps to check:

  • Prime the pump: Remove the pump lid, fill the strainer housing completely with water, replace the lid ensuring the O‑ring is clean and lubricated, then open all valves.
  • Check suction valves: Confirm that the skimmer and main drain valves are open and that any 3‑way valves are correctly positioned.
  • Inspect for air leaks: Look for bubbles in the pump lid while running. Check unions, suction fittings, and the lid O‑ring for cracks or damage. Replace seals as needed.
  • Clean suction line: Remove obstructions from skimmer baskets and vacuum lines. If a line is blocked, use a plumbing snake or professional line cleaning.
  • If E10 persists with good prime: The internal flow/pressure sensor or dry‑run detection circuit in the DAB control module may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

DAB flow/pressure sensor
Check Price on Amazon