E15
DAB External Safety Interlock Open

Pump shows E15 and stops when connected to an external flow or pressure switch

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open external flow switch, Tripped pressure switch, Broken wiring to safety interlock terminals, Misconfigured safety input in DAB settings

How to Fix / Troubleshooting

Safety first: Ensure the system is depressurized and power is off before working on external switches.

Steps to check:

  • Verify external devices: Locate any flow or pressure switches wired to the DAB pump. Confirm they are not tripped and are mechanically sound.
  • Check wiring: Inspect the low‑voltage wiring from the switches to the DAB safety input terminals for breaks or loose connections.
  • Bypass test (temporary): For testing only, and if safe, temporarily bridge the safety input terminals to see if E15 clears. If it does, the external device is faulty and must be replaced.
  • Check configuration: Ensure the DAB control is configured correctly for the type of safety device installed (normally open vs normally closed).
Advertisements

Repair Difficulty

Medium 3/5

Required Part

External flow/pressure switch circuit
Check Price on Amazon