E18
DAB Speed Limit / Torque Limit Exceeded

Pump shows E18 and cannot reach the set speed, running slower than expected

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Excessive system head (too much resistance), Partially blocked impeller, Incorrect speed or torque settings in installer menu, Weak motor due to winding damage

How to Fix / Troubleshooting

Safety first: Turn off power and close valves before opening the pump.

Steps to check:

  • Inspect impeller and volute: Remove the pump wet end and clean any scale, debris, or buildup from the impeller and housing.
  • Check system design: Ensure valves are fully open and that the plumbing size is appropriate for the selected speed.
  • Adjust settings: In the DAB installer menu, verify that maximum speed and torque limits are correctly set for your model.
  • Test at lower speed: Run the pump at a moderate speed and see if E18 clears. If the motor still struggles, internal damage may be present.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

DAB impeller
Check Price on Amazon

We may earn a commission from links on this page.