E12
Flowclear High Pressure / Overload Protection

Display shows E12 and pump stops; may occur when filter pressure is very high.

Advertisements

Possible Causes

Severely clogged Flowclear filter cartridge, Dirty sand in Flowclear sand filter, Closed or partially closed return valve, Blocked return jet or hose

How to Fix / Troubleshooting

Safety first: Turn off and unplug the pump before adjusting valves or opening the filter. Release pressure according to the Flowclear manual.

Steps:

  • 1. Check pressure gauge: On Flowclear sand filter systems, note if the pressure gauge is in the red zone. High pressure indicates restriction on the return side.
  • 2. Backwash or clean filter: Perform a full backwash and rinse on sand filters. For cartridge filters, remove and clean or replace the cartridge.
  • 3. Inspect return line: Check the return hose and pool return fitting for kinks, blockages, or closed valves. Ensure the Flowclear multiport valve (if fitted) is in the correct "FILTER" position.
  • 4. Retest: After restoring normal flow, plug in and restart the pump. If E12 recurs with normal pressure, the pressure/overload sensor or control PCB may be faulty.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Flowclear Sand Filter Valve Assembly
Check Price on Amazon