E12
Flowclear
High Pressure / Overload Protection
Display shows E12 and pump stops; may occur when filter pressure is very high.
Advertisements
Possible Causes
Severely clogged Flowclear filter cartridge, Dirty sand in Flowclear sand filter, Closed or partially closed return valve, Blocked return jet or hose
How to Fix / Troubleshooting
Safety first: Turn off and unplug the pump before adjusting valves or opening the filter. Release pressure according to the Flowclear manual.
Steps:
- 1. Check pressure gauge: On Flowclear sand filter systems, note if the pressure gauge is in the red zone. High pressure indicates restriction on the return side.
- 2. Backwash or clean filter: Perform a full backwash and rinse on sand filters. For cartridge filters, remove and clean or replace the cartridge.
- 3. Inspect return line: Check the return hose and pool return fitting for kinks, blockages, or closed valves. Ensure the Flowclear multiport valve (if fitted) is in the correct "FILTER" position.
- 4. Retest: After restoring normal flow, plug in and restart the pump. If E12 recurs with normal pressure, the pressure/overload sensor or control PCB may be faulty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Flowclear Sand Filter Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements