Flowclear
Overheating Motor
Pump motor housing is excessively hot to the touch during normal operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
High ambient temperature, Blocked cooling vents, Overloaded due to dirty filter, Failing motor bearings
How to Fix / Troubleshooting
Safety first: Unplug the pump and allow it to cool before touching the motor housing.
Steps:
- 1. Improve environment: Move the Flowclear pump out of direct sunlight and ensure good airflow around it.
- 2. Clean vents: Remove debris from motor cooling slots.
- 3. Reduce load: Clean/backwash the filter and ensure all valves are open.
- 4. Check bearings: Listen for bearing noise and feel for roughness when spinning the impeller by hand. Replace the motor assembly if bearings are failing.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flowclear Pump Motor Assembly
Check Price on Amazon