E11
Franklin Electric Speed Feedback / Hall Sensor Error (for sensor-based motors)

Variable-speed pump shows E11 and runs only at limited speed or not at all

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged speed sensor inside Franklin Electric motor, Loose feedback connector between motor and drive, Broken feedback cable, Internal drive logic fault

How to Fix / Troubleshooting

Safety first: Disconnect power before unplugging any motor feedback connectors.

  • Inspect feedback cable: Locate the low-voltage feedback cable between the Franklin Electric motor and the control module. Check for cuts, kinks, or pulled connectors.
  • Reseat connectors: Unplug and firmly reconnect the feedback plug at both motor and drive ends to ensure good contact.
  • Check for pin damage: Examine connector pins for bending or corrosion. Clean gently if corroded.
  • Test at fixed speed: If the drive allows open-loop operation, temporarily run the motor without feedback to confirm basic function (technician only).
  • Replace faulty component: If E11 remains, the internal sensor in the motor or the drive’s feedback circuit is defective. Replace the motor assembly or drive as recommended by Franklin Electric.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Franklin Electric pump motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements