E16
Franklin Electric Current Limit / Torque Limit Active

Display shows E16 and pump speed is limited or pump stops under heavy load

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pump operating against partially closed valves, Clogged filter causing high head, Incorrect torque limit settings in Franklin Electric drive, Oversized impeller on motor

How to Fix / Troubleshooting

Safety first: Turn off power before adjusting valves or opening the pump.

  • Normalize system pressure: Fully open suction and return valves. Backwash or clean the pool filter to reduce system head.
  • Check for obstructions: Inspect the impeller and diffuser for debris that could increase load.
  • Review drive settings: In the Franklin Electric controller, verify that current and torque limits are set according to motor and pump specifications. Do not raise limits beyond recommended values.
  • Confirm impeller size: Ensure the installed impeller matches the pump model and motor horsepower. Replace with the correct Franklin Electric impeller if oversized.
  • Retest: Clear E16 and run the pump. If current limit still activates under normal conditions, the motor may be weak and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Impeller
Check Price on Amazon