Com
Hayward RS-485 Communication Failure

Display shows Com or communication error when connected to Hayward automation; pump may not respond to commands.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected or reversed RS-485 wiring, Broken communication cable, Incorrect address or configuration, Faulty communication port on pump or controller

How to Fix / Troubleshooting

Safety first: Turn off power to both the pump and the automation system before working on wiring.

  • Check cable connections: Verify that the RS-485 cable is securely connected to the communication terminals on both the Hayward pump and the automation panel (e.g., OmniLogic, ProLogic).
  • Polarity: Ensure the A/B (or +/–) terminals are wired consistently on both ends. Reversed polarity will prevent communication.
  • Inspect cable: Look for cuts, kinks, or water damage along the communication cable. Replace if damaged.
  • Address settings: Confirm the pump’s address or ID is correctly set in the automation configuration and does not conflict with other devices.
  • Standalone test: Disconnect the RS-485 cable and try operating the pump from its local keypad. If it works locally but not via automation, the issue is likely in the automation system or cabling.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

RS-485 Communication Cable
Check Price on Amazon