Possible Causes

Failed power components on drive board, Severe surge or lightning damage, Internal short circuits, Overheated drive components

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker. Do not attempt to repeatedly start a pump with a drive error.

  • Visual inspection: Remove the drive cover and look for burned components, bulging capacitors, or a burnt odor.
  • Check for surge damage: If the error appeared after a storm or power event, consider installing surge protection on the pump circuit.
  • Reset attempt: After 5 minutes with power off, restore power and see if the error clears. If it returns immediately, the drive is likely irreparably damaged.
  • Replace drive: Replace the drive/control module or entire motor/drive assembly according to Hayward service instructions.