Er1
Hayward Internal Drive Communication Error

Display shows Er1 and pump will not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose internal control cable, Corrupted drive firmware, Moisture intrusion into drive housing, Failed control PCB

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker before opening any covers.

  • Power cycle: Turn off the breaker for at least 2 minutes, then restore power to reset the drive electronics.
  • Inspect drive housing: Check the control end of the Hayward pump for signs of water intrusion, corrosion, or cracked housing. Any moisture can cause communication errors.
  • Check internal connections: If you are qualified, remove the drive/control cover and verify that all ribbon cables and connectors between the keypad, control board, and power board are fully seated.
  • Firmware/automation: If the pump is connected to a Hayward automation system, disconnect the communication cable (RS-485) and try running the pump in standalone mode to rule out external control issues.
  • Board replacement: If Er1 persists, the control PCB or entire drive module is likely defective and should be replaced as a unit per Hayward service procedures.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Control PCB / Drive Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements