Pr
Hayward Priming Mode Timeout / Failed Prime

Display shows Pr and pump runs at a low speed attempting to prime but does not transition to normal operation.

Advertisements

Possible Causes

Pump not fully flooded with water, Air leak on suction side, Blocked skimmer or main drain, Incorrect priming speed or time settings

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before opening the pump lid.

  • Fill the pump: Remove the pump lid and fill the strainer housing completely with water. Reinstall the lid, ensuring the Hayward lid O-ring is clean and lubricated.
  • Open valves: Confirm all suction valves (skimmer, main drain) are fully open. Close any unused lines that may be drawing air.
  • Check for suction leaks: Inspect unions, fittings, and the pump lid for air leaks. Tighten unions and replace worn O-rings or gaskets.
  • Clean skimmer baskets: Empty all skimmer and pump baskets to ensure unobstructed flow.
  • Adjust priming settings: On variable-speed models, increase the priming RPM and/or priming time in the menu so the pump has enough power and time to establish full prime.
  • Re-test: Restore power and start the pump. If it still cannot prime, further investigation of suction plumbing for blockages or underground leaks may be required.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Pump Lid O-Ring
Check Price on Amazon