Hayward No Power to Pump

Pump will not start at all, no display or lights on Hayward variable-speed pump.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped circuit breaker, Blown fuse in control panel, Loose or disconnected wiring at pump, Failed internal power supply in drive

How to Fix / Troubleshooting

Safety first: Before touching wiring, turn off the main breaker feeding the pool equipment.

  • Check breaker: Locate the breaker labeled for the pool pump and ensure it is in the ON position. Reset if tripped; if it trips again immediately, do not force it—investigate further.
  • Inspect external disconnects: Some installations have a local disconnect or timer. Make sure any switches are ON and timers are not in the OFF position.
  • Verify voltage at pump: With a multimeter and appropriate safety precautions, confirm that rated voltage is present at the pump’s terminal block.
  • Check wiring connections: With power off, remove the electrical cover on the pump and ensure all wires are secure and not burned.
  • Internal failure: If correct voltage is present but the display remains dead, the internal low-voltage power supply or drive board has likely failed and must be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Drive Control Module
Check Price on Amazon

We may earn a commission from links on this page.