F5
Hurlcon Controller–Motor Communication Fault

Controller shows F5 and pump will not start; sometimes occurs after a power surge or lightning storm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged Hurlcon control PCB, Loose low-voltage harness between controller and motor, Corroded connector pins, Power surge damage

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before opening any control enclosures.

  • Power cycle: Turn off the breaker for 2–3 minutes, then restore power and see if the F5 clears.
  • Inspect control cable: Trace the low-voltage cable from the Hurlcon controller to the motor terminal box. Check for cuts, rodent damage, or crushed sections. Ensure plugs are fully seated.
  • Check for moisture: Open the controller housing (if user-accessible) and look for signs of water ingress or corrosion on the PCB. Dry gently with a cloth and allow to air dry if damp.
  • Try manual mode: If the controller has a MANUAL or SERVICE mode, attempt to start the pump from that mode to bypass timers.

If F5 persists, the Hurlcon control PCB or motor interface board is likely damaged and should be replaced by a qualified pool technician or electrician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Hurlcon pump control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements