F7
Hurlcon Speed Selection / Internal Drive Fault

Pump stops and F7 appears, often when switching between speed settings on a variable-speed Hurlcon pump.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty speed selector keypad, Internal drive electronics failure, Loose control ribbon cable, Corrupted firmware on Hurlcon variable-speed drive

How to Fix / Troubleshooting

Safety: Isolate power before removing any covers.

  • Reset drive: Turn off power for 5 minutes, then restore. Attempt to select a single speed and run continuously.
  • Check keypad: Inspect the Hurlcon keypad for stuck buttons, water ingress, or cracked membrane. Gently press each button to ensure it returns freely.
  • Dry moisture: If the keypad or drive housing shows condensation, dry the exterior and improve weather protection (install a cover or shade).
  • Try default program: If the controller allows, reset to factory default speed programs and test operation.

If F7 recurs, the internal drive module or keypad assembly may need replacement. This should be done by a technician familiar with Hurlcon variable-speed pumps.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Hurlcon variable-speed drive module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements