Hurlcon
Loss of Prime / Airlocked Pump
Pump runs but there is no water movement; pump pot does not fill with water.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Air leak on suction side, Low pool water level, Blocked suction line, Pump installed above water level without proper priming
How to Fix / Troubleshooting
Safety: Turn off power before opening the pump lid.
- Check water level: Ensure pool water is at least halfway up the skimmer opening.
- Clean baskets: Empty skimmer and Hurlcon pump baskets.
- Prime pump: Remove pump lid, fill the housing completely with water, lubricate and refit the lid O-ring, then restart the pump.
- Inspect for air leaks: Look for bubbles under the lid and water drips at unions. Tighten fittings and replace any cracked fittings or O-rings.
If the pump still will not prime, the suction line may be blocked or leaking underground and will require professional diagnosis.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Hurlcon pump lid O-ring and suction fittings
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements