Hurlcon
No Power / Dead Pump
Pump will not start at all, no hum, no click, and no display on Hurlcon controller.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped circuit breaker, Blown fuse in Hurlcon controller, Faulty pump power cord, Failed on-board power supply
How to Fix / Troubleshooting
Safety: Do not work on live circuits. If unsure, call an electrician.
- Check breaker and RCD: Inspect the switchboard for a tripped breaker or safety switch. Reset if tripped and observe if it trips again when the pump is turned on.
- Test outlet: For plug-in pumps, plug a lamp or other appliance into the same outlet to confirm power is present.
- Inspect cord and plug: Look for cuts, burns, or loose pins on the Hurlcon pump cord and plug.
- Controller fuse: If accessible, check the small fuse inside the Hurlcon controller and replace with the same rating if blown.
If there is power at the outlet but the pump remains dead, the internal power supply or motor is likely failed and requires professional repair or replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Hurlcon pump power cord or internal power supply
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements