E11
Intex Flow Sensor Error / Stuck Flow Switch

Display shows E11 and pump shuts off during operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty flow sensor, Scale or debris on flow switch paddle, Loose flow sensor wiring, Incorrect flow sensor orientation

How to Fix / Troubleshooting

Safety first: Turn off and unplug the pump. Close any valves before removing the flow sensor.

  • Locate the flow sensor: On Intex combo units (e.g., sand filter with saltwater system), the flow sensor is typically installed in a clear or opaque housing on the return line.
  • Inspect for debris: Remove the sensor assembly and check the paddle or magnetic float for sand, scale, or debris that may prevent free movement. Clean gently with water and a soft brush.
  • Check orientation: Ensure the flow sensor is installed in the correct direction (arrow on body matching water flow direction) and not upside down.
  • Verify wiring: Inspect the sensor cable for cuts or kinks and ensure the connector is fully seated on the control board.
  • Replace sensor: If E11 persists after cleaning and reseating, replace the Intex flow sensor assembly compatible with your model.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Sensor Assembly
Check Price on Amazon

We may earn a commission from links on this page.