E98
Intex Motor / Control Board Mismatch or Severe Motor Fault

Display shows E98 and pump will not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect replacement motor or board installed, Shorted motor windings, Faulty motor position sensor (on variable-speed models)

How to Fix / Troubleshooting

Safety first: Disconnect power before working on the pump.

  • Confirm correct parts: If you recently replaced the motor or control board, verify that the part numbers match your exact Intex model. Using an incompatible board or motor can trigger E98.
  • Inspect motor wiring: Check all motor leads and connectors for loose or damaged wires. Ensure all plugs are fully seated.
  • Check for mechanical seizure: With power off, remove the strainer cover and verify the impeller spins freely by hand. A seized motor can cause E98.
  • Replace assembly: If the motor is shorted or incompatible, replace the entire pump motor assembly with the correct Intex part number. If the motor is good but E98 persists, replace the motor control board.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Pump Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.