SPD ERR
Jandy
Speed Feedback or Control Error
Variable-speed Jandy pump shows SPD ERR or SPEED ERROR and will not maintain set RPM.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty internal speed sensor, Drive electronics malfunction, Incorrect programming or incompatible external control signals
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before removing any covers. Do not attempt to open sealed drive modules.
- Reset programming:
- Enter the pump menu and restore factory defaults.
- Reprogram basic speeds and schedules.
- Isolate from automation:
- If connected to AquaLink or another controller, temporarily disconnect the RS-485 cable.
- Test the pump in standalone mode to see if SPD ERR persists.
- Power cycle:
- Turn off the breaker for 2–3 minutes, then restore power and test again.
- If SPD ERR remains: The internal speed sensor or drive board is likely defective. Replacement of the drive or entire pump is recommended and should be done by a qualified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Variable Speed Drive Module