E06
Kripsol Ground Fault / Earth Leakage Detected

Kripsol variable-speed pump shows E06 and stops; may occur when the pump is wet or after heavy rain.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Moisture ingress into Kripsol motor terminal box, Damaged insulation on motor windings, Water inside Kripsol control panel, Faulty cable between control panel and pump

How to Fix / Troubleshooting

Safety first: This error can indicate a shock hazard. Turn off the main breaker and do not touch the pump if it is in standing water.

  • Dry the area: Ensure the pump pad and surrounding area are dry. If the pump has been submerged, do not attempt to restart it; the motor should be inspected and likely replaced.
  • Inspect terminal box: With power off, open the motor terminal cover. Look for water, condensation, or corrosion. Dry thoroughly with a clean cloth and low-heat air (not open flame). Replace any corroded terminals.
  • Check control panel: Open the Kripsol control box and inspect for water tracks, rust, or dampness. Dry the interior and correct any leaks in conduit or panel seals.
  • Cable inspection: Examine the cable from the control panel to the pump for cuts or crushed sections. Replace if damaged.

If E06 returns after drying and inspection, the motor insulation or drive electronics may be compromised. Have a technician perform insulation resistance tests and replace the motor or drive as needed.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Kripsol pump motor assembly
Check Price on Amazon