E09
Kripsol
Tachometer / Speed Feedback Fault (VS models)
Display shows E09 and pump runs only at very low speed or not at all.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed internal speed sensor in Kripsol variable-speed motor, Damaged feedback wiring between motor and controller, Loose connector on controller PCB, Faulty controller firmware
How to Fix / Troubleshooting
Safety first: Disconnect power before removing covers.
- Inspect connectors: Open the Kripsol variable-speed pump control housing. Locate the low-voltage connector from the motor to the controller PCB. Reseat the connector and check for bent pins or corrosion.
- Check cable condition: Follow the feedback cable from the motor to the controller. Look for cuts, pinches, or signs of rodent damage. Replace the cable if damaged.
- Firmware reset: If available in the menu, perform a factory reset of the controller and re-enter motor parameters. Sometimes E09 is cleared by resetting corrupted settings.
- Motor sensor failure: If wiring and connectors are good, the internal speed sensor in the motor may have failed. This typically requires replacement of the motor assembly or a dedicated sensor module if separately replaceable.
Because this involves low-voltage electronics and proprietary parts, many homeowners choose to have a Kripsol service center handle E09 faults.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Kripsol variable-speed motor assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements