E12
Kripsol Control Panel / Keypad Communication Error

Kripsol controller shows E12 and the keypad or display becomes unresponsive.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose low-voltage ribbon cable between keypad and main PCB, Water ingress into Kripsol keypad module, Failed keypad membrane, Faulty main controller PCB

How to Fix / Troubleshooting

Safety first: Disconnect power before opening the control housing.

  • Inspect keypad cable: Remove the front cover of the Kripsol control panel. Locate the ribbon or plug-in cable from the keypad/display to the main PCB. Reseat both ends and ensure the locking tabs are engaged.
  • Check for moisture: Look for condensation or water marks inside the keypad area. If present, dry thoroughly and improve sealing (replace gasket, check cable glands).
  • Visual inspection: Examine the keypad for cracks or delamination. If buttons feel mushy or do not click, the membrane may be failing and should be replaced.
  • PCB fault: If E12 persists with a known-good keypad and cable, the main controller PCB is likely defective and must be replaced.

Because this involves proprietary electronics, sourcing the correct Kripsol keypad or PCB by model number is important.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Kripsol pump keypad/display module