Kripsol
Improper De-Winterization / Open Drain Points
Pump cannot be primed after winterization; it just sucks air and never fills.
Advertisements
Possible Causes
Pump drain plugs on Kripsol housing not reinstalled or loose, Winterizing plugs left in pool returns or skimmers, Airlock in suction line, Multiport valve left in WINTER or CLOSED position
How to Fix / Troubleshooting
Safety first: Ensure all valves are set correctly before starting the pump.
- Install drain plugs: Verify that all Kripsol pump drain plugs are installed with gaskets and tightened.
- Remove winter plugs: Take out any plugs from skimmers, returns, and other fittings in the pool.
- Set valves correctly: Set the sand filter multiport valve to FILTER and open all necessary suction and return valves.
- Prime thoroughly: Fill the pump housing completely with water, then start the pump. It may take several minutes to purge all air.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Kripsol pump drain plug gasket
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements