Kripsol Unstable Speed Control / Sensor Interference

Pump speed fluctuates up and down on a variable-speed Kripsol pump without user input.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Electrical noise on power supply, Loose control wiring or poor grounding, Faulty speed sensor in motor, Interference from external automation signals

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing control wiring.

  • Check grounding: Ensure the Kripsol pump and control panel are properly grounded and that ground connections are tight.
  • Inspect control cables: Tighten all low-voltage control and communication terminals. Keep control cables separated from high-voltage power cables where possible.
  • Test in standalone mode: Disconnect external automation and run the pump in local/manual mode. If speed stabilizes, the issue lies with the external controller or wiring.
  • Sensor/drive fault: If fluctuations persist in standalone mode, the internal speed sensor or drive electronics may be faulty and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Kripsol variable-speed drive module
Check Price on Amazon

We may earn a commission from links on this page.