Kripsol Timer / Memory Retention Failure

Pump will not hold schedule or timer settings; clock resets after power interruptions.

Advertisements

Possible Causes

Failed backup battery or capacitor on Kripsol controller PCB, Firmware bug, Frequent power outages without surge protection

How to Fix / Troubleshooting

Safety first: Turn off power before opening the control housing.

  • Check user settings: Confirm that time and schedules are being saved correctly per the Kripsol manual; some models require a specific save/enter step.
  • Inspect PCB battery: If accessible, look for a small coin-cell or backup battery on the controller PCB. Replace with the same type if depleted.
  • Use external timer: As a workaround, control the pump from an external Kripsol time clock or automation system and leave the internal schedule disabled.
  • PCB replacement: If the internal memory cannot retain settings, the controller PCB may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Kripsol pump controller PCB
Check Price on Amazon