E09
Lowara Control Panel / Keypad Communication Fault

Pump display shows E09, will not start, keypad unresponsive at times

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose keypad ribbon cable, Moisture ingress into keypad, Faulty control PCB on Lowara drive, Electrical noise or interference on control wiring

How to Fix / Troubleshooting

Safety first: Isolate power before removing any covers. Avoid static discharge to electronic boards.

  • Inspect keypad connection: Remove the front cover of the Lowara drive or control box and check the ribbon cable between the keypad and main PCB. Reseat both ends firmly.
  • Check for moisture: Look for condensation or water marks on the keypad and PCB. Dry gently and improve enclosure sealing if water ingress is evident.
  • Reduce interference: Ensure control cables are routed away from high‑voltage power cables and that all shields/earth connections are as per Lowara’s wiring diagram.
  • Reset the unit: Restore power and attempt a reset. If the keypad remains erratic or E09 persists, the keypad or main control board may be defective.
  • When to call a pro: Replacement of the keypad or main control PCB should be done by a qualified technician using genuine Lowara parts.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Lowara pool pump keypad / main control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements