Lowara
System Overpressure / Discharge Restriction
Pump runs but filter pressure is very high and return jets are weak
Advertisements
Possible Causes
Clogged pool filter, Closed or partially closed return valve, Blocked return line, Undersized piping for pump output, Multiport valve in wrong position
How to Fix / Troubleshooting
Safety first: Turn off pump before changing valve positions or opening filter.
- Backwash or clean filter: If using a sand or DE filter, perform a full backwash and rinse. For cartridge filters, remove and clean or replace cartridges.
- Check valves: Ensure all return valves and the multiport valve are in the correct positions for normal filtration.
- Inspect return lines: Look for obvious kinks or blockages in visible pipework. If underground lines are blocked, professional assistance may be required.
- Verify pump sizing: Confirm the Lowara pump is correctly sized for the filter and plumbing. Oversized pumps can cause high pressure.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements