E05
Pahlen
Motor Overload / Overcurrent on Variable-Speed Drive
Pahlén variable-speed pool pump shows E05 and runs only at reduced speed or not at all
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect speed programming causing excessive load, Blocked impeller in Pahlén pump, Shorted motor windings, Incorrect supply voltage to drive
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before opening the drive enclosure or pump terminal box.
- Check for blockage: Remove the pump strainer basket and inspect for debris. If necessary, open the wet end to ensure the impeller rotates freely and is not obstructed.
- Review speed settings: On the Pahlén variable-speed controller, reduce the maximum RPM or flow setpoint to factory-recommended levels. Avoid running at maximum speed against a highly restricted system.
- Verify filter and valves: Clean the filter and fully open return valves to reduce system resistance and motor load.
- Inspect motor: If the motor housing is extremely hot or emits a burnt smell, internal windings may be damaged. Do not continue to reset E05; seek professional evaluation.
- Reset the drive: After correcting mechanical load issues, power cycle the drive and clear E05 via the control interface. Monitor current draw if the drive displays it.
Advertisements
Repair Difficulty
Hard