E06
Pahlen Flow Sensor / Pressure Switch Fault

Pahlén pump controller displays E06 and pump stops intermittently

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective Pahlén flow switch, Loose wiring to flow sensor, Air trapped in pump or filter, Scale or debris on flow sensor paddle

How to Fix / Troubleshooting

Safety first: Isolate power and close valves before removing any sensor from the plumbing.

  • Bleed air: Open the air relief valve on the filter until a steady stream of water flows. Air pockets can cause erratic flow readings.
  • Inspect sensor wiring: Locate the flow sensor or pressure switch used by the Pahlén controller. Check that the connector is fully seated and that the cable is not damaged or pinched.
  • Clean the sensor: If accessible, remove the flow sensor from its tee fitting. Rinse off scale, sand, or debris from the paddle or probe. Do not use abrasive tools that could damage the sensor.
  • Reinstall correctly: Ensure the sensor arrow aligns with the direction of water flow and that any O-rings are intact and lubricated.
  • Reset and test: Restore power, clear E06 on the control panel, and verify that the pump runs continuously without the error returning.

If E06 persists, the flow sensor itself may need replacement with a compatible Pahlén part.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements