Pahlen Control Interface / Communication Issue

Pahlén pool pump does not respond to automation system commands but runs manually

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect control mode on Pahlén pump, Faulty relay or control output from automation, Broken low-voltage cable, Misconfigured address or protocol

How to Fix / Troubleshooting

Safety first: Turn off power to control circuits before rewiring. Low-voltage circuits can still be damaged by shorts.

  • Verify control mode: Set the Pahlén pump to accept external control (relay, 0–10 V, or RS-485) as required by your automation system.
  • Test manual operation: Confirm that the pump runs correctly in local/manual mode to rule out mechanical issues.
  • Check wiring: Inspect low-voltage control cables between the automation panel and Pahlén pump for continuity and correct terminal connections.
  • Bypass test: Temporarily command the pump using a simple on/off relay or direct 0–10 V signal to verify that the pump responds.