Pahlen Mechanical Shaft Seal Failure

Pahlén pool pump is leaking water between the pump housing and the motor

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn ceramic/carbon mechanical seal, Dry-running of Pahlén pump, Chemical attack from unbalanced water, Incorrect seal installation

How to Fix / Troubleshooting

Safety first: Turn off power and close isolation valves before disassembling the pump. Water may spill when opening the housing.

  • Confirm leak location: Dry the area and observe. If water appears at the joint between the pump volute and motor flange, the mechanical seal is likely leaking.
  • Disassemble wet end: Remove the pump from the plumbing if needed. Open the volute, remove the impeller, and access the mechanical seal assembly according to Pahlén service instructions.
  • Replace seal: Install a new Pahlén-compatible mechanical seal, ensuring that ceramic and carbon faces are clean and not touched with greasy fingers. Press components squarely into place.
  • Reassemble and test: Rebuild the pump, reprime, and run while checking for leaks.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Mechanical Shaft Seal
Check Price on Amazon

We may earn a commission from links on this page.