E07
Pentair Sta-Rite Motor Position / Speed Feedback Error

Pump display shows E07, motor does not start or runs erratically

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed internal sensor in permanent magnet motor, Loose feedback connector between motor and drive, Damaged motor feedback cable, Faulty drive logic circuit

How to Fix / Troubleshooting

Safety: Turn off all power to the pump before removing covers.

  • Inspect feedback harness: On Sta‑Rite variable‑speed pumps, locate the low‑voltage harness between the motor and drive. Ensure the connector is fully seated and free of corrosion or broken pins.
  • Check for cable damage: Look for cuts, kinks, or rodent damage along the harness. Replace the harness if any conductors are exposed or broken.
  • Secure strain relief: Make sure the cable is not being pulled tight by conduit or equipment movement. Re‑route if necessary to relieve stress on the connector.
  • Reset and test: After reseating connectors, restore power and attempt to start the pump. If E07 returns, the internal motor sensor or drive logic is likely defective.
  • Replace assembly as needed: Because the feedback sensor is integral to the motor, the typical repair is replacement of the complete motor assembly or the combined motor/drive kit specified by Pentair Sta‑Rite.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Motor Assembly with Feedback Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements