Pentair Sta-Rite Air‑Bound System / No Discharge Flow

Pump runs but pressure gauge on filter reads zero and there is no circulation

Advertisements

Possible Causes

Pump not fully primed, Air lock in filter or heater, Multiport valve in wrong position

How to Fix / Troubleshooting

Safety: Turn off power before changing valve positions. Open air relief slowly to avoid injury.

  • Prime pump: Fill the Sta‑Rite pump strainer housing with water and ensure the lid o‑ring is sealing properly.
  • Bleed air from filter: With the pump running, open the air relief valve on top of the filter until a steady stream of water comes out, then close it.
  • Check valve positions: Verify that the multiport valve (if present) is set to Filter and that any bypass valves around the filter or heater are correctly positioned.
  • Inspect for internal filter issues: A broken standpipe or missing internal parts can cause no pressure. If suspected, open the filter and inspect internals.
Advertisements

Repair Difficulty

Easy 2/5