Pump display shows E06; motor may start and then shut down or fail to start at all.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker and confirm with a meter before any disassembly.
Steps to address motor feedback errors:
- 1. Power reset: Turn the breaker OFF for several minutes, then restore power and attempt to start the pump. Sometimes transient faults clear with a reset.
- 2. Listen for abnormal sounds: If the motor hums, jerks, or vibrates without reaching speed, immediately shut it off. This indicates improper commutation or winding issues.
- 3. Inspect for moisture and corrosion: Check the motor and drive interface area for signs of water ingress or corrosion on connectors (if accessible). Moisture can damage internal sensors.
- 4. Verify correct programming: Ensure the pump is not being driven by incompatible external automation commands. Reset to factory defaults if recommended by Pentair documentation.
Because the motor feedback circuitry is internal to the SuperFlo VS motor/drive, field repair is not practical. Persistent E06 typically requires replacement of the motor and drive assembly.
Repair Difficulty
Required Part
We may earn a commission from links on this page.