Pentair SuperFlo Debris in Impeller / Damaged Impeller

Pump makes a loud rattling or grinding noise and flow is reduced.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stones or hard debris passed through skimmer, Broken pump basket, Impeller vanes chipped or worn, Foreign object lodged in volute

How to Fix / Troubleshooting

Safety first: Turn off power and close suction and return valves before disassembling the pump.

  • 1. Inspect pump basket: Remove the lid and basket. If the basket is cracked or missing pieces, replace it; debris may have reached the impeller.
  • 2. Access the impeller: Remove the clamp band or housing bolts to separate the motor from the pump housing. Carefully pull the motor/impeller assembly out.
  • 3. Clear debris: Inspect the impeller eye and vanes for rocks, plastic, or other debris. Remove all foreign material. Spin the impeller by hand to ensure it turns freely.
  • 4. Check for damage: If vanes are broken or heavily worn, replace the impeller with a compatible Pentair SuperFlo impeller.
  • 5. Reassemble and test: Reinstall the diffuser, O-rings, and motor assembly. Prime the pump and restore power. Verify noise and flow have improved.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

SuperFlo Impeller
Check Price on Amazon

We may earn a commission from links on this page.