Pentair SuperFlo Thermal Overload Cycling

Pump motor runs briefly and then shuts off, repeating this cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overheating due to blocked ventilation, High ambient temperature, Overloaded motor from mechanical binding, Incorrect voltage

How to Fix / Troubleshooting

Safety first: Turn off power and allow the motor to cool before touching.

  • 1. Check for mechanical drag: Spin the motor shaft by hand with power OFF. If stiff, investigate bearings or impeller obstruction.
  • 2. Improve cooling: Clear debris from vents and ensure adequate airflow around the motor.
  • 3. Verify voltage and load: Have an electrician confirm correct supply voltage and that the pump is not overloaded by closed valves or a blocked filter.
  • 4. Replace motor if needed: Persistent thermal cycling despite proper conditions indicates internal motor issues; replacement is recommended.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

SuperFlo Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements