Pentair SuperFlo
Leaking Pump Unions
Pump runs but there is a persistent small leak at the union connections near the pump.
Advertisements
Possible Causes
Loose union nuts, Misaligned plumbing, Damaged union O-rings, Cracked union body
How to Fix / Troubleshooting
Safety first: Turn off power and relieve system pressure before tightening unions.
- 1. Tighten unions: Hand-tighten union nuts firmly. Use a strap wrench if needed, but avoid overtightening.
- 2. Inspect O-rings: Disassemble unions and inspect O-rings for cuts, flattening, or chemical damage. Replace as needed.
- 3. Check alignment: Ensure plumbing lines are not putting side-load on the unions. Realign or support piping if necessary.
- 4. Replace cracked unions: If the union body is cracked, replace with compatible Pentair union fittings.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
SuperFlo Union O-Rings
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements