Alarm 002
Pentair High Line Voltage / Overvoltage Condition

IntelliFlo3 VSF or similar Pentair pump shows “Alarm 002” and will not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Line voltage above specified maximum, Incorrect service voltage supplied to pump, Utility or transformer issue, Surge event damaging drive input

How to Fix / Troubleshooting

Safety first: Do not operate the pump until the supply voltage is confirmed safe.

  • Step 1 – Measure line voltage: Have a licensed electrician measure the voltage at the pump and at the service panel. Compare to pump rating.
  • Step 2 – Correct supply: If the pump is connected to an incorrect voltage (e.g., 277 V), rewire to the proper 230 V circuit.
  • Step 3 – Contact utility if needed: If the service voltage is consistently high, the power company may need to adjust the transformer tap.
  • Step 4 – Inspect drive: If Alarm 002 appeared after a lightning or surge event and the pump will not run even with corrected voltage, the drive may be damaged and require replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

IntelliFlo3 Drive Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements