Alarm 003
Pentair
Motor Overload / Overcurrent
IntelliFlo3 VSF or similar Pentair pump shows “Alarm 003” and shuts down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked impeller, Seized motor bearings, Incorrect programming causing excessive load, Internal motor fault
How to Fix / Troubleshooting
Safety first: Turn off power and lock out the breaker before disassembling the pump.
- Step 1 – Inspect wet end: Remove the pump lid and basket. Check for debris lodged in the impeller. If necessary, separate the pump housing to fully inspect and clean the impeller and diffuser.
- Step 2 – Check shaft rotation: With the wet end removed, spin the motor shaft by hand. If it is stiff, noisy, or does not spin freely, the bearings are likely failing.
- Step 3 – Review programming: Ensure the pump is not programmed to run at maximum RPM against closed valves or a very restrictive system. Open valves and reduce RPM if needed.
- Step 4 – Replace motor/drive: If mechanical components are clear and Alarm 003 persists, the motor or drive is likely defective and should be replaced as a unit.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
IntelliFlo3 Motor and Drive Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements