Union Seal Leak
Pump housing or plumbing is leaking at the unions connected to a Pentair IntelliFlo or SuperFlo VS pump.
Advertisements
Possible Causes
Loose union nuts, Damaged union O‑rings, Misaligned plumbing putting stress on unions, Cracked union body from overtightening or freezing
How to Fix / Troubleshooting
Safety first: Turn off pump and relieve system pressure before loosening unions.
- Step 1 – Tighten unions: Hand‑tighten the suction and discharge union nuts. Do not use large wrenches that can crack the fittings.
- Step 2 – Inspect O‑rings: If leaking persists, shut off valves, loosen unions, and inspect the O‑rings. Replace flattened, cracked, or missing O‑rings with Pentair‑specified replacements and apply a light coat of silicone lube.
- Step 3 – Check alignment: Ensure the connected PVC plumbing is properly aligned and not forcing the unions off‑center. Correct any misalignment with additional fittings or supports.
- Step 4 – Replace cracked unions: If the union body is cracked, replace the union kit designed for your Pentair pump model.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Pentair Pump Union Kit with O-Rings
Check Price on Amazon