Pentair
Control Logic / Automation Override Issue
Pump speed changes unexpectedly or does not follow the programmed schedule on Pentair IntelliFlo or IntelliFlo3.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
External automation (EasyTouch/IntelliCenter) overriding local schedule, Multiple conflicting schedules programmed, Stuck relay or incorrect wiring from automation, Faulty control board
How to Fix / Troubleshooting
Safety first: Turn off power before working on control wiring.
- Step 1 – Check automation mode: If the pump is connected to Pentair automation, verify whether it is set to be controlled by the automation system rather than local schedules.
- Step 2 – Review schedules: On the pump keypad, review and simplify schedules to avoid overlapping programs that can cause speed changes.
- Step 3 – Inspect control wiring: Ensure that any relay or RS‑485 connections are wired per Pentair diagrams and that no unintended control signals are present.
- Step 4 – Test standalone: Temporarily disconnect automation and run the pump in standalone mode. If behavior normalizes, reconfigure the automation system.
Advertisements
Repair Difficulty
Medium
3/5
Advertisements