PS
Raypak Water Pressure Switch Open

Display shows PS or PRESS SW error; Raypak unit will not start or shuts down shortly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low system pressure due to dirty filter, Incorrect pressure switch adjustment, Failed pressure switch diaphragm, Blocked heater inlet or outlet

How to Fix / Troubleshooting

Safety first: Turn off power and relieve water pressure before removing any pressure switch or plumbing components.

  • Restore normal pressure: Clean or backwash the pool filter and ensure all valves are fully open. Check for obvious leaks on the suction side that could reduce pressure.
  • Inspect heater unions: Make sure the inlet and outlet unions at the Raypak manifold are fully tightened and gaskets are intact, preventing air from entering.
  • Check pressure switch tubing: Some Raypak models use a small tube from the manifold to the pressure switch. Inspect for kinks, cracks, or blockages and clear or replace as needed.
  • Adjust or replace switch: If your model has an adjustable pressure switch, follow the Raypak manual to set it correctly (usually with a small screw). If adjustment does not help, replace the pressure switch.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements